LG Dryer Error Codes: Complete 2026 Guide

MOST COMMON ERROR CODES · LG DRYERS d90 / d95 — Airflow Blockage clogged duct · blocked vent cap · crushed hose ★★★★★ d80 — Partial Duct Blockage lint trap · flex hose kink · annual cleaning ★★★★☆ tE / tE1 — Thermistor Fault open sensor · loose connector · $10–$25 part ★★★☆☆ nP — No Power to Heater tripped 240V leg · faulty outlet · wiring ★★☆☆☆ HE — Heating Element Fault open element · thermal cutoff · $25–$65 part ★★☆☆☆ Frequency ranking based on field service data · LG electric & gas dryers · DLGX, DLE, DLG, DLEX, DLHC series
Quick answer

LG dryers use a compact error-code vocabulary across electric and gas models. The five most frequent codes are: d90/d95 (airflow blockage ≥ 90% — clean the duct immediately, this is a fire-hazard category), d80 (partial blockage ≥ 80% — dryer slows but keeps running), tE1 (inlet thermistor fault — power cycle, then check connector before replacing the $10–$25 sensor), nP (no power to the heater — check both legs of the 240V breaker), and HE (heating element open circuit — test continuity, replace element and thermal cutoff together). Start every diagnosis with a 30-second power cycle. Codes that survive a reset point to a real hardware fault — use the section guides and full table below to isolate which one.

Electric vs. Gas: Which Codes Apply to Your LG Dryer

LG sells both electric dryers (model numbers starting with DLE, DLEX, DLHC, DLEC) and gas dryers (DLG, DLGX). Most error codes are shared, but the heating-system codes diverge:

  • Electric dryers: Use HE for heating element failures and nP for missing 240V supply. The machine needs two 120V legs from the outlet to power the element; if one leg drops out, the drum still turns but nP appears and there is no heat.
  • Gas dryers: Do not show HE (no heating element). Gas ignition faults may not produce a visible code on all models — symptoms are a drum that runs but clothing stays cold. nP on a gas dryer usually means the 120V supply to the gas valve solenoids is missing.
  • Both types: Share all airflow codes (d80, d90, d95), thermistor codes (tE series), EHE (on condenser models), CL, and PS.

How to confirm your model type: Find the label inside the door opening (on the frame around the drum). The model number starting with DLE or DLEX is electric; DLG or DLGX is gas. If the label is worn, the ApplianceIQ serial decoder can identify the fuel type from the model number alone.

Power-Cycle Reset: Start Here Before Anything Else

Every LG dryer error code guide — including LG's own — starts with the same step: a full power cycle. Here is the correct procedure:

  1. Press Power to end the current cycle.
  2. Unplug the dryer from the wall outlet, or trip both poles of the circuit breaker to the OFF position simultaneously.
  3. Wait 30 seconds (some techs recommend 60 seconds for newer control boards).
  4. Restore power and run a short timed-dry cycle — typically a 20-minute low-heat run — and watch for the code to return.

A code that disappears after a reset and does not come back was triggered by a transient event (power surge, momentary sensor glitch). A code that returns immediately or within one cycle confirms a physical fault — proceed to the relevant section below. For d80/d90/d95 airflow codes, do not resume drying until the duct obstruction is cleared, even if the code disappears after a reset.

d80 / d90 / d95 — Airflow Blockage Codes (Fire-Hazard Category)

LG's "d" codes are the most important codes in this guide — and the most dangerous to ignore. They represent blockage percentage in the exhaust path: the dryer's onboard sensors measure exhaust temperature against drum temperature and infer how restricted airflow has become.

15,500
Home dryer fires reported annually in the US — and clogged exhaust vents are the single leading cause, according to CPSC and NFPA data.
Source: U.S. Consumer Product Safety Commission and NFPA Dryer Fire Statistics

d80 — 80–89% Blockage

With a d80 code, the dryer has detected that the exhaust pathway is 80–89% obstructed. The machine will continue operating, but it slows efficiency dramatically: cycle times increase, clothes come out damp, and the restricted hot air bakes lint into a progressively denser plug. This is a warning, not a safety stop — but it is only one cleaning session away from d90 or d95.

On gas dryers only: d80 can also appear when the gas supply pressure is insufficient. If you have confirmed the exhaust duct is clear, check that the gas shutoff valve behind the dryer is fully open and that other gas appliances in the home are operating normally.

d90 — 90%+ Blockage: Dryer Pauses

At d90, the dryer detects blockage of 90% or more. The machine interrupts the cycle, drops to a cool-down sequence, and will not resume heating until airflow is restored. This is LG's automatic safety intervention: continuing to heat with 90%+ restriction creates temperatures inside the duct that can ignite trapped lint.

d95 — 95%+ Blockage: Dryer Stops

d95 is the most severe airflow code. The dryer shuts down the heating system immediately and will not restart a heated cycle. d95 typically means the duct is almost entirely blocked — often by years of accumulated lint, a crushed flexible hose behind the unit, or an outdoor vent cap sealed shut by paint, pests, or debris.

Clearing d80 / d90 / d95: Step-by-Step

  1. Clean the lint screen — before every load, every time. A partially blocked screen contributes to all three d codes.
  2. Inspect the flexible transition hose behind the dryer. Pull the dryer away from the wall. Look for sharp bends, kinks, or sections that have been crushed by the machine being pushed too close to the wall. Replace any damaged flexible duct with a rigid or semi-rigid aluminum duct — LG recommends a maximum duct length of 8 feet for flexible duct.
  3. Clean the full exhaust duct run with a dryer duct cleaning brush kit (available for ~$20–$35 at hardware stores). Feed the brush from the outside vent cap inward, or use a drill-powered brush kit for longer runs.
  4. Inspect the outdoor vent cap. The flap should open freely when the dryer runs and close when it stops. Flaps clogged with lint, paint, or debris are a very common d95 trigger. Clean or replace the cap ($8–$20).
  5. Run a timed-dry cycle after cleaning. If the d code does not reappear, the fix is complete. If d80 or above returns within a few cycles, you have a longer duct run with a hidden obstruction — consider professional duct cleaning.
LG dryer airflow codes — severity and recommended action
CodeBlockage levelDryer behaviorSafe to run?Action
d8080–89%Continues, slower dryingNo — fix nowClean lint trap, hose, duct run
d9090–94%Pauses, cools downNoFull duct cleaning before restarting
d95≥ 95%Stops immediatelyNoFull duct cleaning + vent cap inspection

tE / tE1 / tE2 / tE4 — Thermistor Fault Codes

LG dryers use two thermistors: an inlet thermistor that measures incoming air temperature and an outlet thermistor that measures exhaust air. The tE codes identify which sensor is at fault and the nature of the failure.

tE / tE1 — Inlet Thermistor Open or Out of Range

tE (or tE1) is the most common thermistor code and almost always refers to the inlet thermistor. The sensor has an open circuit, a short to ground, or is reading a temperature outside the expected operating window. The dryer will not heat when tE1 is active, because the control board cannot confirm safe operating temperatures.

Diagnosis steps:

  1. Power cycle (30 seconds unplugged). If tE1 clears and does not return, it was a transient glitch.
  2. If it returns, locate the thermistor — on most LG dryer models it is clipped to the inlet duct near the heating element housing. Disconnect the wiring harness and inspect the connector for corrosion, bent pins, or cracked insulation. Reconnecting a corroded connector resolves tE1 in a meaningful number of cases.
  3. Test the thermistor with a multimeter set to resistance (kΩ). At room temperature (~70°F / 21°C), a good LG inlet thermistor reads approximately 10–50 kΩ. A reading of 0 Ω (short) or OL (open) confirms the sensor has failed.
  4. Replace the thermistor. Common part number: 6323EL2001B (fits many DLGX, DLG, DLEX, DLE models — confirm your model before ordering). Cost: $10–$25. Replacement takes approximately 20 minutes with basic tools.

tE2 — Outlet Thermistor or Steam-Cycle Thermistor

tE2 often appears after a SteamFresh, Steam Sanitary, or Steam Option cycle. During steam cycles, exhaust air humidity spikes sharply; in cold environments or with a partially restricted duct, the sudden change in exhaust temperature can trigger the outlet thermistor's out-of-range threshold. LG's own support documentation notes that tE2 is particularly common in cold-weather laundry rooms or after steam cycles when the duct cools quickly.

First step for tE2: ensure the exhaust duct is unobstructed (a d80 condition can co-exist with tE2). If tE2 appears consistently without steam cycles and airflow is confirmed clear, test and replace the outlet thermistor using the same resistance-check procedure as tE1.

tE4 — Thermistor Out of Operating Range

tE4 indicates that one of the dryer's temperature sensors is reading a value so far outside the expected range that the control board cannot safely operate the heater. Unlike tE1/tE2, tE4 can sometimes be caused by a failing control board rather than the sensor itself. Confirm by testing the sensor resistance first. If the sensor reads in range, the issue is likely in the harness or the board's measurement circuit — which requires professional service.

$10–$25
Typical cost for an LG dryer thermistor (part 6323EL2001B and equivalents). Labor to install takes about 20 minutes — one of the fastest and cheapest dryer repairs.

nP / PS — Power Supply Codes

Power supply codes are less about the dryer itself and more about what is happening at the electrical panel or outlet. Both codes are diagnostic — they mean the dryer is reporting an anomaly in its incoming power, not that an internal component has failed.

nP — No Power to Heating Circuit

nP stands for "No Power" (to the heater). On an electric dryer, the drum motor and display run on 120V from one leg of the outlet; the heating element requires the full 240V (both legs combined). When one leg is present but the other is missing, the drum turns normally and the display works — but the heater gets nothing, and nP appears.

The most common cause is a half-tripped circuit breaker. A 240V circuit uses a double-pole breaker (two switches tied together). After a surge, one pole can trip while the other stays on — from the front of the panel it may look like the breaker is still "on." Always reset a 240V breaker by pushing it fully to OFF and then to ON, even if it does not appear tripped.

If the breaker is confirmed fully reset and nP persists, the outlet itself may be faulty (a broken terminal contact inside the outlet body is common after power events). Test the outlet with a 240V voltmeter or plug in a known-working appliance. Replace the outlet if voltage is absent on one leg.

PS — Power Supply / Terminal Block Wiring Error

PS (Power Supply error) indicates that the dryer's control board is detecting incorrect voltage polarity at the terminal block — specifically, the white (neutral) and red (L2) wires have been reversed. This typically happens after an installation or repair where the dryer was rewired without following the color-coded terminal block diagram inside the back access panel.

PS requires turning off the breaker, opening the terminal block access panel, and verifying that the connections match LG's wiring diagram: Black → L1 terminal, Red → L2 terminal, White → neutral terminal, and the green or bare copper wire → ground lug. Never work on the terminal block with the breaker energized.

HE / EHE — Heating Element and Heater Overcurrent Codes

HE — Heating Element Fault (Electric Dryers)

HE on an LG electric dryer means the control board detected that the heating element circuit drew no current, or less current than expected, when the heater was commanded on. The three most common causes:

  1. Open heating element: The element's coil has physically broken (burned through). Test with a multimeter in resistance mode — a good element reads 8–12 Ω. No continuity (OL) confirms the element is open and must be replaced ($25–$65 DIY).
  2. Blown thermal cutoff (TCO): LG dryers have a one-shot thermal cutoff designed to trip if the dryer overheats — often caused by restricted airflow (see d codes above). A blown TCO reads no continuity and must be replaced (~$10). Crucially: always replace the TCO and heating element together. A burned-out element usually means the TCO was stressed past its limit; replacing only the TCO will likely result in another failure within weeks.
  3. High-limit thermostat failure: The cycling thermostat that sits on the heater housing can also open permanently after repeated overheating. Test for continuity in the same way. Replacement cost: $12–$20.

Before ordering a heating element, confirm there is no active airflow restriction — running the dryer with a blocked duct will burn out a new element just as quickly as it burned out the old one.

EHE — Heater Overcurrent (Condenser Dryers)

EHE (and its companion ELE) appears primarily on LG condenser dryers — ventless models that recirculate air through a heat exchanger rather than exhausting it outside. EHE means the heater is drawing more current than the control board considers safe, often because the drum is packed with excessively wet laundry or because the condenser filter is clogged with lint.

For EHE: power cycle, then clean the condenser filter (accessible behind a lower panel on most condenser models — LG recommends cleaning it every 3–5 cycles). If EHE returns after cleaning, the heater relay on the control board may have failed, which requires professional service.

CL and Other Informational Codes

Not every code on an LG dryer display is an error. These notifications appear like codes but require no repair:

LG dryer informational codes — not errors
CodeMeaningAction
CLChild Lock is active — buttons are locked outHold the Child Lock button for 3 seconds to deactivate
dFDoor open — cycle cannot startClose door firmly; check door switch if it persists
AddAdd items reminder (during cycle, on some models)Open door, add garments, close, and resume

Full LG Dryer Error Code Reference Table

Complete LG dryer error code reference — electric and gas models
CodeWhat it meansFirst stepDIY fixEst. cost
d80Exhaust 80–89% blockedClean lint screen + ductYes$0–$35 (brush kit)
d90Exhaust 90–94% blocked, dryer pausesFull duct cleaning before restartYes$0–$35
d95Exhaust ≥ 95% blocked, dryer stopsFull duct + vent cap inspectionYes$0–$50
tE / tE1Inlet thermistor open or out of range30s power cycle; check connectorYes$10–$25
tE2Outlet/steam thermistor faultConfirm duct clear; check harnessYes$10–$25
tE4Thermistor reading severely out of rangeTest sensor resistance; check harnessSometimes$10–$150
nPNo power detected to heating circuitReset both poles of 240V breakerYes (breaker); Pro (wiring)$0–$15 outlet
PSPower supply / reversed wiring on terminal blockTurn off breaker; verify wiring diagramCaution — electrical work$0
HEHeating element open circuit (electric only)Test element continuity; check TCOYes$35–$75 (element + TCO)
EHEHeater overcurrent (condenser models)Clean condenser filter; power cycleSometimes$0–$200
CLChild Lock active (not an error)Hold Child Lock button 3 secondsYes$0
dFDoor openClose door; check latchYes$0–$25

DIY vs. Call a Tech: Decision Guide

Most LG dryer error codes resolve with a cleaning, a breaker reset, or a $10–$25 sensor. Here is when to draw the line:

LG dryer repair decision matrix
ScenarioDIY?Reason
d80/d90/d95 — duct is accessible and under 10 feetYesStraightforward cleaning; $20–$35 brush kit
d95 — duct runs through a wall or ceilingProfessionalHidden obstruction; professional duct cleaning recommended
tE1 — thermistor replacementYesSingle screw, clip connector, 20 minutes
nP — breaker reset clears itYesOne-step fix
nP — breaker is fine but still no heatProfessionalOutlet or wiring fault; shock hazard
PS — reversed terminal block wiringCautionRequires 240V electrical work; turn off breaker first
HE — element and TCO replacementYesCommon repair; many walkthrough guides available
tE4 or EHE after cleaning and sensor checkProfessionalMay require control board diagnosis

Repair vs. Replace: The Math for LG Dryers

LG dryers have an average lifespan of 10–13 years with normal use. Use the 50% rule as the starting threshold: if repair cost exceeds 50% of a comparable new dryer's price (currently $600–$1,100 for mid-range LG models), replacement often makes more economic sense.

  • d95 / duct cleaning on a unit under 10 years old: Always repair. Cleaning costs $0–$50 DIY or $80–$150 professional. No parts are failing — this is maintenance.
  • tE1 thermistor on any age unit: Always repair. $10–$25 part, 20-minute job. Even on a 12-year-old dryer, this is worth doing.
  • HE (element + TCO) on a unit under 8 years old: Repair. $35–$75 is well under threshold for a machine worth $600–$900 new.
  • HE (element + TCO) on a unit over 10 years old: Repair if it is the first major failure. On the second major failure in a 24-month window, apply the 50% rule and likely replace.
  • tE4 or EHE requiring control board replacement on a unit over 8 years old: Evaluate carefully. Control boards cost $150–$300 installed, which approaches 30–50% of a new dryer's price. Factor in the overall condition of the drum seal, belt, and rollers — if multiple components are near end-of-life, replacement is usually more economical.

For a structured decision framework, see our appliance repair-vs-replace decision tree and 2026 repair cost math guide. For LG's overall reliability track record, see appliance lifespan by brand.

Before scheduling a service call, run your LG dryer's model and serial number through ApplianceIQ. It returns the exact manufacture date (important for determining whether the motor or drum is still under LG's limited warranty), active recall status, and estimated remaining lifespan — so you go into the repair conversation with full context. Free tier includes 25 lookups/month. You can also check your LG serial number to decode the manufacture date manually.

Frequently Asked Questions

What does d90 mean on an LG dryer?
d90 on an LG dryer means the exhaust duct is at least 90% blocked, preventing adequate airflow through the machine. The dryer will pause the cycle and enter a cool-down mode to prevent overheating. Clean the lint screen first, then inspect the full length of the exhaust duct for kinks, lint accumulation, or a stuck outdoor vent flap. Do not resume drying until airflow is restored — d90 and d95 are fire-hazard codes. The CPSC reports that clogged dryer vents contribute to approximately 15,500 home fires per year in the US.
What does tE1 mean on an LG dryer?
tE1 on an LG dryer means the inlet thermistor — the temperature sensor that measures incoming air — has an open circuit or is reading outside its normal range. Try a 30-second power cycle first. If tE1 returns, check the wiring harness connector at the thermistor for corrosion or a loose pin. If the connector is secure and the thermistor reads outside 10–50 kΩ at room temperature on a multimeter, replace it. The inlet thermistor (part 6323EL2001B on many LG models) costs $10–$25 and takes about 20 minutes to replace.
What does nP mean on an LG dryer?
nP (No Power) on an LG dryer means the control board cannot detect current to the heating circuit, even though the display and drum motor may work normally. On an electric dryer this almost always means the dryer is receiving only one of its two required 120V legs — the drum turns but there is no heat. Check whether only one leg of the 240V breaker tripped, and reset both poles fully to OFF then ON. If the breaker is fine, the outlet should be tested with a voltmeter. On a gas dryer, nP can indicate a missing 120V supply to the gas valve solenoids.
What does HE mean on an LG dryer?
HE on an LG electric dryer indicates a fault with the heating element or its circuit — the element is not drawing the expected current. Test the heating element for continuity with a multimeter; an open element shows no continuity and must be replaced ($25–$65 DIY). Always replace the thermal cutoff (about $10) at the same time, since a burned-out element usually means the cutoff has been stressed. HE does not appear on gas dryers.
How do I reset LG dryer error codes?
Press the Power button to end the current cycle, then unplug the dryer from the wall outlet (or trip both poles of the circuit breaker). Wait a full 30 seconds to allow the control board to fully discharge. Plug back in and run a short timed-dry cycle to confirm the code is gone. If the same code returns immediately, the underlying hardware fault is real — a reset confirms the diagnosis but does not fix the problem. For d80/d90/d95 airflow codes, do not run the dryer again until the duct blockage is physically cleared.
Do LG dryer error codes differ between electric and gas models?
Most LG dryer error codes are the same across electric and gas models. The d80/d90/d95 airflow codes, tE thermistor codes, and nP code appear on both types. However, HE (heating element failure) is specific to electric dryers — gas dryers heat via a burner assembly that does not produce a HE code. EHE appears primarily on condenser-type ventless dryers. Always confirm your model type before ordering replacement parts.
Is it safe to run my LG dryer when it shows d80?
Running a dryer on a d80 code is not recommended. A d80 code means 80–89% of the exhaust pathway is blocked. The dryer continues operating at reduced efficiency, but the restricted airflow causes lint to accumulate at temperatures that can lead to ignition. The CPSC consistently identifies clogged vents as the leading cause of dryer fires. At d90 the dryer pauses on its own; at d95 it stops. Do not bypass these safety shutdowns — clean the duct before resuming operation.